From Rack Testing to Hall-Level Thermal Validation
When the commissioning scope extends beyond one rack, the standard family provides larger controlled liquid loads that can be deployed by zone, CDU or hall and combined into a phased test plan.
Hall and cooling level | Liquid load
Scale controlled thermal load from individual racks to AI halls and cooling zones.

Controlled commissioning load
A standard family of liquid-cooled resistive load platforms for AI hall heat-load testing, CDU capacity and stability testing, liquid-distribution commissioning and modular multi-unit deployments.
Published equipment data
| Model | Power | Voltage | Reference size | Weight |
|---|---|---|---|---|
| LB-300 | 300 kW | 380 / 400 / 415 / 480 V | 1700 x 1150 x 1300 mm | 1400 kg |
| LB-400 | 400 kW | 380 / 400 / 415 / 480 V | 1700 x 1150 x 1300 mm | 1500 kg |
| LB-500 | 500 kW | 380 / 400 / 415 / 480 V | 1700 x 1150 x 1300 mm | 1600 kg |
| LB-600 | 600 kW | 380 / 400 / 415 / 480 V | 1700 x 1150 x 1300 mm | 1700 kg |
Commissioning applications
Final test responsibilities and procedures remain governed by the approved project commissioning plan and the CxA.
Technical context
When the commissioning scope extends beyond one rack, the standard family provides larger controlled liquid loads that can be deployed by zone, CDU or hall and combined into a phased test plan.
Standard 300, 400, 500 and 600 kW ratings allow the project team to match temporary thermal demand to the cooling architecture. Each standard unit supports 1 kW loading resolution.
Use the load banks to exercise CDU capacity, control stability, liquid-distribution response and facility heat rejection under staged and extended demand conditions.
Multiple units can be planned around commissioning phases, test zones and available interfaces. Special voltage, power and physical configurations can be reviewed against project requirements.
Local touchscreen operation is standard, with optional remote-control capability. Electrical parameters and liquid-side temperature, flow and pressure functions can be monitored during test execution.
Typical uses include AI hall heat-load testing, cooling-system capacity validation, retrofit or expansion testing and modular deployments that build demand in controlled phases.
Amor can support capacity review, equipment configuration, mobilization, temporary interfaces, setup, operation, troubleshooting and coordination with the CxA, GC, EC and mechanical teams.
How this equipment is used
Controlled demand for power, cooling, controls and subsystem response.
Review applicationThermal load for rack, CDU, liquid-loop and cooling-system validation.
Review applicationPredictable electrical and thermal conditions while facility systems change state.
Review applicationAMOR deployment & field support
Equipment and field support for L4 functional performance testing, heat-load testing and L5 integrated systems testing under the approved project commissioning plan.
Project requirements
Tell us enough about the power, cooling architecture and commissioning stage to begin the correct equipment review.
Request load capacity review